7.4. Troubleshooting and display information
8. Maintenance and care
8.1. Lens-cleaning cloth
You can clean high sensitive lens surfaces with the enclosed
special microfibre cloth. It is suitable for objective lens, ocu-
lar lens and spectacles.
Please keep the cloth clean, as dirt can damage the lens
surface. If the cloth becomes soiled it can be washed in
lukewarm soapy water and left to dry. Please only use for
cleaning lens surfaces!
8.2. Cleaning
We have designed all elements and surfaces to require little
care.
To ensure the long-lasting optical brilliance of your binocu-
lars, you should keep the glass surfaces free of dirt, oil and
grease. When cleaning the lenses, first remove larger par-
ticles with an optical lens brush. For the subse-
quent thorough cleaning we recommend breathing
onto the lens surface to form a coat of condensa-
tion and then cleaning it with a soft, moist cloth.
The housing is best cleansed with a soft, moist cloth (don’t
use the lens-cleaning cloth).
In the event of hard-to-remove dirt (e.g. sand) the eye cups
can be unscrewed and cleaned easily.
Problem Probable Cause Remedy
The field of view is
shaded at the
periphery (vignetted).
The eyecups have
not been adjusted
correctly for use with
or without spectacles.
Spectacle wearers
need to twist the eye-
cups right in to the
stop position. When
using without spec-
tacles, the eyecups
need twisting out to
the required position
(see chapter 3.1.).
The display shows
“----” for the distance
measured.
1. The measurement
range has been
exceeded.
2. The object is not
reflective enough.
3. Target out of focus.
1. See chapter 4.
2. See chapter 7.1.
3. See chapter 3.5.
The display shows
“co” for the distance
measured (clean
optic).
1. The distance to
the target is shorter
than the minimum
measurement range.
2. The objective lens
is dirty.
1. See Technical Data
Sheet.
2. Clean the objective
lens.
The aiming mark
flashes when the
instrument is
switched on.
The battery is low. There is sufficient
power for around 100
more measurements.
Replace the battery
or briefly warm the
current one.
Display, aiming mark
and target are not all
in focus at same time.
Dioptric adjustment is
not optimal.
See chapter 3.4.
“Err” appears on the
display
Electronic fault Press the measure-
ment button again.
On repeated
occurrence of “Err”,
please contact
SWAROVSKI OPTIK
customer service.